Hydro Kleen Double Pumping Unit
Note: - Two fumace passes decoked simultaneously for speed and efficiency
  • 2 x 430hp Caterpillar or Detroit Diesel Engines
  • 2 x 7,500 liters/minute Waterous CMUD 'Two Stage' Water Pumps
  • 10 x 4" (100mm) Electronically Controlled Air Actuated Ball Valves
  • 2 x Pressure/Flow Computerized Data Recorders
  • Dual Operation Control Positions
  • 6,000 liter capacity dirty water reservoir/tank
  • 11,400 liter capacity clean water reservoir/tank
  • Tank Unit Primary Filtration
  • 2 inch (50mm) tank connection filler - for connection to refinery fireline supply
  • 160m x 3" (75mm) diameter hard and flexible hammerlock pressure rated tubing for connections between Pumping Unit and furnace access points
  • All pressure rated (1000psi) hammerlock fittings (elbows and couplings)
  • Drainage flexible hoses for dirty tank overflow discharge
  • Launcher/receiver units - all sizes - complete with pressure seal 'Huber' doors
  • Full bore ball valves connected to all launchers to control pig launch & receive
  • Water and compressed air connections to all HKS launcher/receiver
Note: - All launcher connections to furnace inlets/outlets are 300# RF all Connection and launching equipment is certified to 1000 psi (70 bar G)